OOLER Repair Kit A
How to easily repair your OOLER sleep system with the OOLER Repair Kit A.
Table of Contents

Use Caution
Before beginning any repairs, please ensure you follow general electrostatic discharge (ESD) safety procedures to protect your device from damage.
Use Only Genuine Repair Parts
What you'll need
Parts
Tools
Tool 1 | Phillips screwdriver |
Tool 2 | Wire cutters |
Supplies | System Cleaner Packet |
Supplies | Bucket, Distilled Water, Clean Damp Cloth |
Ready the OOLER for Disassembly
Click to expand instructions
Unplug the Power Cord: Disconnect the power cord from the OOLER.
Unplug the Water Feed Hose: Disconnect the water feed hose from the OOLER. *Note: Keep a rag handy for any spilled water.
Attach the Drain Key: Secure the Drain Key to the OOLER.

Drain Water: Position the OOLER over a bucket, holding it at an angle with the drain key pointed downward to drain water from the unit.

Drain remaining water: Align the OOLER reservoir opening over the bucket to pour out any remaining water from the unit.
OOLER Repair Kit A
Remove the Front Plate
- Remove the eight (8) Phillips screws securing the chassis from the underside of the OOLER.

- Depress the left- and right-side locking tabs and pull the front plate straight off.
![]() |
![]() |
Remove the Top Cover
- Remove the two (2) Phillips screws that fasten the top cover to the bottom cover.

- Unplug the flat-flex display cable from the main-board.

- Lift top cover off from bottom base cover.

Remove the Water Pump
- Unplug the water pump power cable from the main-board.

- Remove the two (2) Phillips screws holding the pump bracket to the base.

- Cut the two zip-ties securing the inlet and outlet tubes to the pump.

- Place an absorbent towel beneath the pump, then pull both tubes off the pump ports—expect minor water leakage.
- Remove the water pump from the chassis and set it aside.
Remove the Water Tank
- Peel off the securing tape (save it for re-use).

- Cut and discard the zip-tie bundling the cables.

- Cut and discard the zip-tie securing the fan cable.

- Unplug the following connectors from the main-board:
- Red: Water temperature sensor
- Blue: Water level sensor
- White: UV Light

- W.O.P. 2 black wires with blue insulation.

- Remove the four (4) Phillips screws securing the water tank to the base.

- Cut the two zip-ties that fix the hose to the chassis.

- Disconnect the hose from both the water tank nipple and the CPC quick-connect fitting. Retain the hose jacket.
Remove the Heat Exchanger
- Remove the ground screw from the heat-sink.

- Disconnect the hose from the lower CPC quick-connect fitting by cutting the zip tie.

- Lift the heat exchanger and tilt the unit to a 45-degree angle.

- Remove the four (4) Phillips screws holding the water block cover and set aside.

- Replace the three water hoses, reusing the existing tube sleeves, and secure the hoses using the supplied zip ties.

Reassembling the OOLER
Click to expand instructions
Install the Heat Exchanger
Secure Water Block Cover:
- Align the water block cover over the heat exchanger and fasten the cover with the four (4) Phillips screws.
Position Heat Exchanger:
- Carefully lower the heat exchanger into its position in the chassis.
Reconnect Lower Hose:
- Attach the hose to the lower CPC quick-connect fitting and secure with a zip tie.

Install Ground Screw:
- Fasten the ground wires to the heat-sink using the ground screw.

Install the Water Tank
Connect Hose:
- Replace the hose between the water tank and the water pump by first removing the clamp, then securing the hose to the tank with a zip tie.
![]() |
![]() |
Connect Hose:
- Ensure the hose jacket is in place.
- Attach the hose to the water tank nipple and the CPC quick-connect fitting.
- Fix the hoses to the chassis using two zip ties.

Secure Water Tank:
- Position the water tank in the base.
- Fasten it using the four (4) Phillips screws.

Connect Main-board Connectors:
- Plug in the following connectors to the main-board:
- Red: Water temperature sensor
- Blue: Water level sensor
- White: UV Light

- W.O.P.: 2 black wires with blue insulation

Bundle and Secure Cables:
- Bundle cables as needed and secure with a new zip tie.
- Secure the fan cable with a zip tie.
- Reapply the securing tape to hold the assembly in place.

Install the Water Pump
Place Water Pump:
- Position the water pump in the chassis.
Attach Tubes:
- Slide both the inlet and outlet tubes onto the pump ports.
- Secure each tube with a new zip tie.

Secure Pump Bracket:
- Fasten the pump bracket to the base using the two (2) Phillips screws.

Connect Pump Power:
- Plug the water pump power cable into the main-board.

Install the Top Cover
Position Top Cover:
- Place the top cover onto the bottom base cover.
- Fasten the top cover to the bottom cover with the two (2) Phillips screws.

Connect Display Cable:
- Plug the flat-flex display cable into the main-board.

Secure Front Cover
Fasten the eight (8) Phillips screws securing the chassis from the underside of the OOLER.

Instructions for Refilling Your OOLER
- Open the reservoir and add one packet of System Cleaner.
- Fill the reservoir with distilled water.
- Using a clean damp cloth, wipe down the control unit to keep it clean and functioning properly.
- Power up the OOLER and check for leaks.
- Refill the water tank as necessary until the system is completely filled.
- Reattach the cap to seal the tank.
If you have any questions or concerns, don't hesitate to get in touch with our Customer Experience Team.