E1 Error

Common causes and solutions for resolving E1 errors in troubleshooting guide.

Written by Denver Dublada

Updated at April 16th, 2025

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Chilipad Dock Pro
    Setup and Maintenance Troubleshooting Frequently Asked Questions Repair Guides
  • Sleepme Mobile App
    Setup and Installation Frequently Asked Questions Troubleshooting Hiber-AI
  • Sleep Tracker
    Setup and Installation Sleepme+ Tips, Tricks & Best Practices Troubleshooting Frequently Asked Questions
  • Orders
  • Frequently Asked Questions
    Sleep Health and Wellness Terms of Service
  • Chilipad Cube
    Setup and Maintenance Frequently Asked Questions Troubleshooting Repair Guides
  • OOLER
    Setup and Maintenance OOLER App Frequently Asked Questions Troubleshooting
  • Accessories
    Weighted Blankets
+ More

Table of Contents

E1 Error Disconnect hose and flip the connection. Disconnect the Dock Pro Try to Dislodge the Check Valve Attach the Drain Key Check Water Flow How to clean the Check Valve Tools Ready the Dock Pro for disassembly Click to expand instructions Removing the Check Valve Click to expand instructions Check Valve Reassembly Click to expand instructions Reassembling the Dock Pro Click to expand instructions Instructions for Refilling Your Dock Pro Additional Help

E1 Error

If you encounter an E1 error on your display, the unit has automatically turned the mini-pump on and off five times in an effort to resolve the issue. The E1 error typically indicates one of two issues: a stuck check valve or an airlock. Follow the steps below to troubleshoot and resolve the error.

 

Chilipad Dock Pro E1 Error

 

Disconnect hose and flip the connection.

  • Reversing the connection alters the water intake flow from one side to the opposite side.
  • Power on the Dock Pro to see if the error clears. Proceed to the next step if error persists.

 

Disconnect the Dock Pro 

  • Detach your Dock Pro from the hose and bring it to a sink or bathtub where you can conveniently plug it in, or alternatively, use a bucket.

 

Try to Dislodge the Check Valve

  • The following instruction is applicable only to a Dock Pro unit equipped with a black manual check valve. If your Dock Pro features a black/white check valve or an electric solenoid, this instruction does not apply.
  • Shake the Unit: Before turning it on, gently shake the unit from side to side and front to back to help dislodge the metal ball in the check valve.

 

Chilipad Dock Pro E1 Error

 

Attach the Drain Key

  • Attach Drain Key: While the unit is still powered off, attach the drain key.

 

Attach drain key to the Chilipad Dock pro

 

Check Water Flow

  • Fill the Reservoir:
  • With the drain key attached and the unit powered off, fill the reservoir with water and place it back in the housing.
  • Observe the flow of water from the drain key. If the water flows freely, everything is functioning correctly.
  • If the flow is obstructed, the check valve may be stuck and requires cleaning.

 

The following instructions are applicable only to Dock Pro units equipped with black manual check valves. If your Dock Pro features black/white check valve or electric solenoid, these instructions do not apply.

Try cleaning the check valve before proceeding with the retrofit of the electric check valve solenoid.

Check water flow

 

How to clean the Check Valve

Tools

Tool 1 Phillips screwdriver or poker rod
Supplies Isopropyl Alcohol 70% or higher
Supplies System Cleaner Packet
Supplies Cup, Distilled Water, Clean Damp Cloth

 

Ready the Dock Pro for disassembly


Click to expand instructions

Unplug the Power Cord: Disconnect the power cord from the Dock Pro.

Unplug the Water Feed Hose: Disconnect the water feed hose from the Dock Pro. *Note: Keep a rag handy for any spilled water.

Remove the Water Reservoir: Take the water reservoir out of its housing.

Dump the Water: Remove the reservoir, then detach the lid and transfer the water into a bucket..

Attach the Drain Key: Secure the Drain Key to the Dock Pro.

Drain Water: Position the Dock Pro over a bucket, holding it at an angle with the drain key pointed downward to drain water from the unit.

Drain remaining  water: Align the Dock Pro reservoir opening over the bucket to pour out any remaining water from the unit.

Flip the Dock Pro: Turn the Dock Pro on its side to access the screws.

Remove the Screws: Using a screwdriver, take out the 8 screws.

Reposition the Dock Pro: Once the screws are removed, set the Dock Pro back upright.

Lift the Cover: Lift the cover partially away from the Dock Pro to Identify the display cable connected to the control board, identify the display cable connected to the control board.

Disconnect the Display Cable: Carefully detach it, and then set the Dock Pro housing aside.

 

 
 

Removing the Check Valve

Click to expand instructions

Cut Zip Ties: Cut the zip ties that are bundling the cables.


Unplug Power Cables: Unplug the Air Solenoid power cables from the control board.


Unplug Water Level Sensor: Unplug the Reservoir Water Level Sensor cables from the control board.


Disconnect Air Line: Unplug the air line from the Air Solenoid by cutting the zip. 


Remove Reservoir Housing: Unscrew the 3 screws holding the Reservoir Housing to the base to remove it.


Remove Water Line from Reservoir Outlet: Cut the zip tie holding the water line connected to the Reservoir Outlet and remove the hose.


Set Reservoir Water Aside: Remove Check Valve and set the Reservoir Water aside for later use.

 

 
 

Example of a stuck closed check valve: This issue can occur when distilled water is not used, leading to mineral deposits or microbial growth. To prevent stuck closed check valves, it's essential to use distilled water and Chilipad System Cleaner.

Chilipad Dock Pro valve

 

Valve

Dislodge the Metal Ball: Take a small screwdriver or a poker.  

Dislodge the Metal Ball

Carefully push the metal ball to dislodge it from its current position. 

Dislodge the Metal Ball

Prepare for Soaking: Obtain Isopropyl Alcohol (70% or higher). 

Soak the Check Valve: Place the check valve in a container (fully submerged).  Allow it to soak for a 15 minutes to ensure proper cleaning or treatment.  

Soak the Check Valve

Check Valve Reassembly

Click to expand instructions

Reattach check valve: Reattach the check valve to the mini pump, securing it with zip ties at both ends and to the reservoir outlet.


Secure Mount Reservoir Housing: Screw the 3 screws holding the Reservoir Housing to the base.


Connect Air Line: Connect air line from the air solenoid to reservoir housing. Secure the connection with a zip tie.


Plug Power Cables: Plug the Air Solenoid power cables to the control board.


Plug Water Level Sensor: Pug the Reservoir Water Level Sensor cables to the control board.


Secure the cable bundle: Combine cables by using the provided zip ties.

 

 
 

Reassembling the Dock Pro

Click to expand instructions

Retrieve the Dock Pro Housing: Take the Dock Pro housing that was previously set aside.

Reconnect the Display Cable: Carefully attach the display cable back to the control board.

Lower the Cover: Gently lower the cover back into place on the Dock Pro.

Reposition the Dock Pro: Set the Dock Pro upright.

Reinsert the Screws: Using a screwdriver, insert and tighten the 8 screws securely.

Flip the Dock Pro: Turn the Dock Pro back to its original upright position.

Reattach the Water Reservoir: Place the water reservoir back into its housing.

Reconnect the Water Feed Hose: Attach the water feed hose back to the Dock Pro.

Plug in the Power Cord: Reconnect the power cord to the Dock Pro.

 
 

Instructions for Refilling Your Dock Pro

  1. Open the reservoir and add one packet of System Cleaner.
  2. Pour in distilled water as needed to fill the reservoir.
  3. Using a clean damp cloth, wipe down the control unit to keep it clean and functioning properly.
  4. Power up the Dock Pro and check for leaks.

 

Additional Help

If you have followed all the steps and the issue persists, please contact our Customer Experience Team for further assistance.

 

 

solution error code e1 error e1 airlock stuck valve check valve

Was this article helpful?

Yes
No
Give feedback about this article

Related Articles

  • Dock Pro Not Pumping Water into Pad
  • Sleep System Monthly Maintenance
  • Dock Pro and Sleep Tracker Network Connectivity Troubleshooting Guide
  • Dock Pro Not Powering Up
Products
Chilipad Dock ProChilipad CubeSleep Tracker by SleepmeChilipad Matress Protector
Resources
MindfulnessWellnessBlogDeveloper API
Company
About UsCareers
Info
AccessibilityWarrantyPatentsShipping & Returns
Work With Us
Partners & AffiliatesBulk Sales
Customer Support
Customer Service and Product Support Military and First Responder DiscountHSA/FSA Eligibility
Products
Chilipad Dock ProChilipad CubeSleep Tracker by SleepmeChilipad Matress Protector
Resources
MindfulnessWellnessBlogDeveloper API
Company
About UsCareers
Info
AccessibilityWarrantyPatentsShipping & Returns
Work With Us
Partners & AffiliatesBulk Sales
Customer Support
Customer Service and Product Support Military and First Responder DiscountHSA/FSA Eligibility
Sleepme
Link to the Sleepme Instagram account. Link to the Sleepme Twitter account. Link to the Sleepme YouTube account. Link to the Sleepme Facebook account.

© 2025 Sleep Solutions Inc. All Rights Reserved.
Privacy Policy |
Terms & Conditions |
California Privacy Rights and Notice at Collection |
Expand