How to replace the power supply in your Cube

Written by Denver Dublada

Updated at April 10th, 2025

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Chilipad Dock Pro
    Setup and Maintenance Troubleshooting Frequently Asked Questions Repair Guides
  • Sleepme Mobile App
    Setup and Installation Frequently Asked Questions Troubleshooting Hiber-AI
  • Sleep Tracker
    Setup and Installation Sleepme+ Tips, Tricks & Best Practices Troubleshooting Frequently Asked Questions
  • Orders
  • Frequently Asked Questions
    Sleep Health and Wellness Terms of Service
  • Chilipad Cube
    Setup and Maintenance Frequently Asked Questions Troubleshooting Repair Guides
  • OOLER
    Setup and Maintenance OOLER App Frequently Asked Questions Troubleshooting
  • Accessories
    Weighted Blankets
+ More

Table of Contents

Use Caution Overview What you'll need Parts Tools Ready the Cube for disassembly To Replace Power Board Reassembly of Cube Instructions for Refilling Your Cube

 

 

Chilipad Cube Power Board

 

30 minutes
Medium

 

Use Caution

Before beginning any repairs, please ensure you follow general electrostatic discharge (ESD) safety procedures to protect your device from damage. 

Use Only Genuine Repair Parts

 

 

Overview

Replacing the board board is straightforward. Prioritize safety by unplugging the unit before you start. To ensure further protection, you may want to disconnect all components from the control board before removing the supply.

 

What you'll need

 

Parts

  • Cube - Power Supply Repair Kit

 

Tools

Tool 1 Long Phillips Screwdriver (5 inch shank minimum)
Tool 2 Wire cutters
Tool 3 System Cleaner Packet
Tool 4 Bucket, Distilled Water, Clean Damp Cloth

 

 

Ready the Cube for disassembly


Click to expand instructions

Removing Chilipad Cube Housing

Before starting any repair, ensure the Chilipad Cube is completely powered off and unplugged.


Unplug Power Cord: Disconnect the power cord from the wall outlet.


Unplug Water Connection: Remove the water line from the unit.


Attach the Drain Key: Secure the Drain Key to the Cube.


Drain Water: Ensure all water is drained from the unit to prevent spills.


Remove 8 Screws: Use the Philips screwdriver to remove the eight screws holding the Cube housing.


Last Screw: Remove the QC Pass sticker to access the last screw.


Disconnect Display Board Cable Harness: Carefully disconnect the display board cable harness from the control board.


Remove Cube Housing: Gently lift and remove the Cube housing from the base.

 
 

To Replace Power Board

Remove 3 Cable connections: Disconnect the three cables connected to the power board.

Replace Chilipad Cube Power Board

Remove 4 Screws: Use the screwdriver to remove the four screws securing the power board.

Chilipad Cube Power Board

Replace Power Board: Swap out the old board with a new one.


Reassembly of Cube 

Click to expand instructions

Reattach Cube Housing: Position the Cube housing carefully over the base and ensure that all alignments are correct and that no wires are pinched or obstructed.

Reconnect Display Board Cable Harness: Carefully reconnect the display board cable harness to the control board, making sure the connection is tight and secure.


Secure Cube Housing with Screws: Using a Philips screwdriver, reinsert and tighten the eight screws for the Cube housing, being careful not to overtighten.


Reconnect Water Line: Reattach the water line to the unit, ensuring it is securely fastened to prevent leaks.


Plug in Power Cord: Reconnect the power cord to the wall outlet, ensuring that the connection is secure and stable.

 

 
 

Instructions for Refilling Your Cube

  • Open the reservoir and add one packet of System Cleaner.
  • Fill the reservoir with distilled water.
  • Using a clean damp cloth, wipe down the control unit to keep it clean and functioning properly.
  • Power up the Cube  and check for leaks.
  • Refill the reservoir as necessary until the system is completely filled.
  • Reattach the cap to seal the reservoir.

 

f you have any questions or concerns, don't hesitate to get in touch with our Customer Experience Team.

control board electric panel

Was this article helpful?

Yes
No
Give feedback about this article

Related Articles

  • Power Supply
Products
Chilipad Dock ProChilipad CubeSleep Tracker by SleepmeChilipad Matress Protector
Resources
MindfulnessWellnessBlogDeveloper API
Company
About UsCareers
Info
AccessibilityWarrantyPatentsShipping & Returns
Work With Us
Partners & AffiliatesBulk Sales
Customer Support
Customer Service and Product Support Military and First Responder DiscountHSA/FSA Eligibility
Products
Chilipad Dock ProChilipad CubeSleep Tracker by SleepmeChilipad Matress Protector
Resources
MindfulnessWellnessBlogDeveloper API
Company
About UsCareers
Info
AccessibilityWarrantyPatentsShipping & Returns
Work With Us
Partners & AffiliatesBulk Sales
Customer Support
Customer Service and Product Support Military and First Responder DiscountHSA/FSA Eligibility
Sleepme
Link to the Sleepme Instagram account. Link to the Sleepme Twitter account. Link to the Sleepme YouTube account. Link to the Sleepme Facebook account.

© 2025 Sleep Solutions Inc. All Rights Reserved.
Privacy Policy |
Terms & Conditions |
California Privacy Rights and Notice at Collection |
Expand